Calibration Procedures
Calibration Overview
Calibration ensures accurate color, white balance, and depth measurements. Regular calibration is recommended for consistent results.
Calibration Frequency:
- After first setup: 2-3 times
- Weekly for daily use: Once per week
- Monthly for occasional use: Once per month
- After temperature change: After 30+ minutes
- After moving camera: Before critical work
Pre-Calibration Checklist
White Balance Calibration
Method 1: Using White Reference Card
Required Materials:
- White balance reference card (included)
- 18% gray card (optional, for advanced calibration)
Procedure:
- Position Reference Card
- Place white card in front of camera
- Ensure full coverage of frame
- Position at normal working distance
- Avoid shadows on card
- Ensure even lighting
- Capture Reference Image
- Open RobotAI Camera software
- Navigate to Calibration > White Balance
- Click Capture White Reference
- Camera captures image of white card
- Do not move card during capture
- Apply Calibration
- Software analyzes white reference
- Click Apply Calibration
- “Success” message confirms
- New white balance saved
- Verify Results
- Remove white card
- Check live view colors
- Colors should appear neutral
- Test on neutral gray object
Method 2: Manual Color Temperature
For Known Lighting Conditions:
- Determine color temperature of lighting
- Open Settings > White Balance > Manual
- Enter color temperature in Kelvin
- Apply to current settings
Common Color Temperatures:
- Daylight: 5500K
- Cloudy: 6500K
- Tungsten bulb: 3200K
- Fluorescent: 4500K
- LED: 3000-5600K (varies)
Color Accuracy Calibration
Using ColorChecker Passport
Required Materials:
- X-Rite ColorChecker Passport or similar
- Neutral lighting
- Calibration software (included)
Procedure:
- Capture ColorChecker Image
- Position ColorChecker in scene
- Ensure even lighting
- No shadows on card
- Fill ~50% of frame
- Capture image
- Analyze Color Data
- Open Calibration > Color Accuracy
- Load ColorChecker image
- Software identifies color patches
- Calculates color accuracy
- Generates correction profile
- Apply Color Profile
- Review color analysis results
- Delta E values < 2 are excellent
- Click Generate Profile
- Profile applied to camera
- Save profile with date
Verification
- Capture new ColorChecker image
- Compare with calibration target
- Colors should match within Delta E < 1
Depth Calibration
Depth Accuracy Calibration
Required Materials:
- Calibration plate (included)
- Flat, rigid surface
- Level surface
- Ruler or measuring tape
Procedure:
- Prepare Calibration Setup
- Place calibration plate on flat surface
- Ensure plate is level
- Position camera perpendicular to plate
- Measure distance: 300mm to 1500mm
- Mark measurement distance
- Capture Calibration Data
- Open Calibration > Depth
- Enter actual distance to plate
- Click Capture Calibration
- Camera captures depth map
- Process multiple distances
- Multi-Point Calibration
- Capture at 5-7 different distances
- Recommended: 300mm, 500mm, 700mm, 900mm, 1100mm, 1300mm, 1500mm
- Each point improves accuracy
- Allow 10 seconds between captures
- Analyze Results
- Software calculates calibration curve
- Displays accuracy at each distance
- Average accuracy should be < ±1mm
- Graphs show any systematic errors
- Apply Calibration
- Click Apply Depth Calibration
- New calibration saved
- Restart software to apply fully
Depth Quality Verification
After Calibration:
- Capture test objects at various distances
- Compare camera measurements to actual
- Accuracy should meet specifications
- Document results for reference
Geometric Calibration
Lens Distortion Calibration
Required Materials:
- Flat checkerboard pattern
- Printed or displayed pattern
- Flat surface for mounting
Procedure:
- Capture Distortion Reference
- Display checkerboard pattern
- Fill entire camera frame
- Capture multiple angles
- Tilt pattern ±30 degrees
- Capture 5-10 images
- Analyze Distortion
- Open Calibration > Geometric
- Load checkerboard images
- Software detects grid points
- Calculates distortion coefficients
- Identifies barrel or pincushion distortion
- Apply Correction
- Review distortion analysis
- Click Calculate Distortion Map
- Apply correction to all captures
- Save calibration data
Thermal Calibration
Temperature Compensation
Camera automatically compensates for temperature changes, but manual calibration improves accuracy.
Procedure:
- Cold Calibration (below 10°C)
- Allow camera to stabilize at cold temperature
- Open Calibration > Thermal
- Click Capture Cold Reference
- Camera records baseline
- Warm Calibration (above 35°C)
- Allow camera to warm up
- Click Capture Warm Reference
- Records warm baseline
- Apply Thermal Compensation
- Software creates compensation curve
- Automatically adjusts for temperature
- Improves accuracy across temperature range
Periodic Calibration Validation
Weekly Validation
- Capture white balance reference
- Compare to stored profile
- If Delta E > 2, perform full white balance calibration
- Document results
Monthly Comprehensive Check
- Perform white balance calibration
- Perform color accuracy calibration
- Verify depth accuracy at 3 distances
- Check geometric distortion
- Document all results
- Generate calibration report
Calibration Management
Save Calibration Profile
- After successful calibration
- Click Save Calibration As…
- Enter profile name with date
- Example:
Calibration_2024_07_22_Office_Lighting
- Add notes about conditions
Load Calibration Profile
- Open Calibration > Load Profile
- Select calibration from list
- Software loads all settings
- Apply when conditions match
Calibration History
View Calibration Log:
- Settings > Calibration > History
- Shows all calibrations performed
- Date, time, location, conditions
- Results and accuracy metrics
- Ability to revert to previous calibration
Troubleshooting Calibration
Common Issues
“Calibration Failed” Message:
- Ensure reference card properly positioned
- Check for shadows on card
- Verify lighting is stable
- Try again in different location
- Clean camera lens
Poor Color Accuracy After Calibration:
- Lighting may have changed
- Perform new calibration
- Verify reference card is white
- Check ColorChecker for damage
Depth Accuracy Errors:
- Ensure calibration plate is level
- Verify distance measurements
- Perform multi-point calibration
- Check plate for damage or warping
Inconsistent Results:
- Allow longer warm-up time
- Stabilize room temperature
- Perform thermal calibration
- Reduce environmental vibration
Best Practices
- Calibrate on Installation - Perform full calibration before first use
- Consistent Lighting - Calibrate in typical working conditions
- Document Environment - Note temperature, lighting, location
- Regular Validation - Check accuracy weekly
- Multiple Profiles - Create profiles for different lighting conditions
- Archive Results - Keep historical calibration data
- Clean Lens - Clean optics before calibration
- Stable Setup - Use rigid mounting during calibration
See Also